L-0.2, r. 1 - Regulation respecting the application of the Act respecting medical laboratories and organ and tissue conservation

Full text
221. This vehicle must be equipped, in the attendant’s cabin, with the following interior electrical group:
(a)  1-110 V, 15 minimum ampere double socket, connected to the socket located outside;
(b)  1-12 V double socket; and
(c)  lighting of a minimum of 430 lux measured on the floor in the entire cabin.
The second battery, contemplated in the third paragraph of section 209, must be connected so as to be always “charging” without “discharging”, with a 2 position distributor placed at a premise allowing the driver to use the spare battery by turning the distributor, if the main battery can no longer start the motor.
Each inlet contemplated in this section must be identified according to its voltage and source.
R.R.Q., 1981, c. P-35, r. 1, s. 221.